Health, Safety & Environmental Bulletin No 265

                                     K Parmentier – 29 September 2011



                                             Cherry Picker Fatality



           Please see enclosed self-explanatory safety alert issued by JCI.

           This incident again shows the  importance of carrying out a last minute risk assessment
           and  always checking the area for overhead hazards before using any elevated equipment
           (MEWPs, towers, ladders, or scaffold).

           The following extract from our site rules gives appropriate distances for working near
           power lines, but always check the site specific conditions:

              Rule 23 - Do not work within 5.2m of electricity cables slung off wooden poles or

              within  7m  of  cables  attached  onto  steel  power  pylons  – if in doubt, ask  - don’t
              work!  Do not operate tall machinery (hiabs / MEWPS) within 9m of cables slung
              from  wooden  poles  or  15m  from  steel  pylons.  (Distances  obtained  from  HSE

              AIS8rev2).




           Risk management is a big step towards accident prevention; however, it is dependent on the risk firstly
           being identified, then controlled. We need safety awareness to be instinctive and form an integral part
           of both our working and home lives; it is this, in turn, that may save the lives of others. Remember: if
           shared, risks can be mitigated before they pose a threat.

           If  you  have  any  queries  regarding  the  Safety  Bulletin  content  or  require  further  information  please
           contact any staff member of Xmo Strata Ltd.