Example replaced with appropriate gland:












































           Installation  of gland:

           The  installation  method  varies  depending  upon the gland manufacturer, however most gland follow a
           similar design.   The steel armour is cut and sprayed out to the outer  section of the gland body, ensure
           none the armour has been left inside the gland and that the strands are evenly spaced without crossing.

           Some  glands  have  a  separate gripping ring that should be pushed into position to hold the strands in
           place.